Eaton CL1208-6-100TR-R - 6-Phase 100 nH per phase Power Inductor, 0.45 mOhm DCR
Eaton CL1208-6-100TR-R - 6-Phase 100 nH per phase Power Inductor, 0.45 mOhm DCR

Eaton CL1208-6-100TR-R - 6-Phase 100 nH per phase Power Inductor, 0.45 mOhm DCR

Share
Eaton CL1208-6-100TR-R: 6-phase multi-phase power inductor, 100 nH per phase, 0.45 mOhm DCR, 15 A rated per phase.
    • Product Details
    • Download

    Eaton CL1208-6-100TR-R - 6-Phase 100 nH per phase Power Inductor, 0.45 mOhm DCR

    CL1208-6-100TR-R at a glance: 6-phase multi-phase power inductor, 0.45 mOhm DCR, 15 A rated current per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCL1208-6-100TR-R
    Number of phases6
    Rated inductance per phase100 nH ±20%
    Open circuit inductance (OCL)400 nH typical / 360 nH minimum
    Full load inductance (FLL)320 nH minimum
    DC resistance (DCR)0.45 mOhm
    Rated current per phase15 A
    Peak current per phase56 A
    PackageCL1208 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 6 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.

    Copper loss rises with temperature - roughly half the DCR change over the working range. A part running hot is a part with more loss, which is a feedback loop worth keeping an eye on in a densely populated board.

    Where This Series Fits

    CL1208 是 100 nH 多相电感,2 / 3 / 4 / 6 相,DCR 低到 0.45 mOhm。

    • Typical use: 高电流多相 VRM、GPU 供电.
    • 低 DCR 是这个系列的核心卖点:损耗低,效率高。代价是对电流纹波和相间平衡设计要求更高。
    • Data sheet 4314; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 400 nH typical / 360 nH minimum measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. 6 phases is a high-current configuration. Per-phase current is low enough that copper loss stays small even with 15 A in each winding, which is the whole point of going to this many phases.

    Frequently Asked Questions

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    Can I use fewer phases than the part number?
    No. The part number fixes the phase count and the pinout that goes with it.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-cl1208-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.