Eaton CLH1110R1-3-R050-R: 3-phase multi-phase power inductor, 50 nH per phase, 0.23 mOhm DCR, 25 A rated per phase.
    • Product Details
    • Download

    Eaton CLH1110R1-3-R050-R 3-Phase VRM Inductor 50 nH per phase, 25 A Rated

    CLH1110R1-3-R050-R at a glance: 3-phase multi-phase power inductor, 0.23 mOhm DCR, 25 A rated current per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCLH1110R1-3-R050-R
    Number of phases3
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)300 nH typical / 240 nH minimum
    Full load inductance (FLL)200 nH minimum
    DC resistance (DCR)0.23 mOhm
    Rated current per phase25 A
    Peak current per phase140 A
    PackageCLH1110 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The 25 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.

    DCR 0.23 mOhm is why the 3-phase version exists. Halving the current per phase by doubling the phase count cuts the loss per phase by four, and the total inductor loss with it.

    Where This Series Fits

    CLH1110R1 是 R1 版 50 nH 多相电感,OCL 300 nH,DCR 低到 0.23 mOhm。

    • Typical use: 服务器多相 VRM、高端 GPU 供电.
    • H 系列是 CL 系列里 DCR 最低的一档,适合对效率敏感的场合。
    • Data sheet 4313; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    OCL is the open-circuit inductance: 300 nH typical / 240 nH minimum measured with no DC bias. In the circuit the core is biased by the phase current and the inductance falls - the datasheet gives FLL as the value at rated current, and that is the number to use for ripple calculation. 3 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 3-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    How do the phases connect?
    The datasheet gives the pin numbering for each phase pair - (3-4)(5-6) and so on - and the layout has to keep each phase current loop tight.

    Is this part RoHS compliant?
    Yes - the -R suffix on the part number denotes the RoHS build.

    What is Isat?
    The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.