| Parameter | Value |
|---|---|
| Orderable part number | CLH1110R1-4-R050-R |
| Number of phases | 4 |
| Rated inductance per phase | 50 nH ±20% |
| Open circuit inductance (OCL) | 300 nH typical / 240 nH minimum |
| Full load inductance (FLL) | 200 nH minimum |
| DC resistance (DCR) | 0.23 mOhm |
| Rated current per phase | 25 A |
| Peak current per phase | 140 A |
| Package | CLH1110 footprint (see drawing) |
| Packaging | TR - tape and reel |
| RoHS | Compliant (-R suffix) |
A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 4 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.
DCR 0.23 mOhm at 20 °C is the number that sets efficiency. At 25 A per phase the winding loss is 0.1 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.
CLH1110R1 是 R1 版 50 nH 多相电感,OCL 300 nH,DCR 低到 0.23 mOhm。
Isat marks where the part leaves its inductive region. At 25 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.
Can I use fewer phases than the part number?
No. The part number fixes the phase count and the pinout that goes with it.
What does the phase count mean?
The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.
What does the phase count mean?
The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.
Design note: use the full-load inductance and the hot-case
DCR for the loss budget, and check the layout keeps each phase current loop closed.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.