Eaton CLH1110R1-4-R050-R 4-Phase Multi-Phase Power Inductor, 50 nH per phase
Eaton CLH1110R1-4-R050-R 4-Phase Multi-Phase Power Inductor, 50 nH per phase

Eaton CLH1110R1-4-R050-R 4-Phase Multi-Phase Power Inductor, 50 nH per phase

Share
Eaton CLH1110R1-4-R050-R: 4-phase multi-phase power inductor, 50 nH per phase, 0.23 mOhm DCR, 25 A rated per phase.
    • Product Details
    • Download

    Eaton CLH1110R1-4-R050-R 4-Phase Multi-Phase Power Inductor, 50 nH per phase

    CLH1110R1-4-R050-R: 4-phase power inductor, OCL 300 nH typical / 240 nH minimum, DCR 0.23 mOhm, 25 A per phase.

    Electrical Specifications

    ParameterValue
    Orderable part numberCLH1110R1-4-R050-R
    Number of phases4
    Rated inductance per phase50 nH ±20%
    Open circuit inductance (OCL)300 nH typical / 240 nH minimum
    Full load inductance (FLL)200 nH minimum
    DC resistance (DCR)0.23 mOhm
    Rated current per phase25 A
    Peak current per phase140 A
    PackageCLH1110 footprint (see drawing)
    PackagingTR - tape and reel
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    A multi-phase inductor splits one input into several smaller rails so that each phase carries a fraction of the total current. The point is copper loss: total loss goes as I²R, so dividing the current across 4 phases cuts the resistive loss by roughly the square of the phase count, and lets the magnetics run at a lower flux density.

    DCR 0.23 mOhm at 20 °C is the number that sets efficiency. At 25 A per phase the winding loss is 0.1 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.

    Where This Series Fits

    CLH1110R1 是 R1 版 50 nH 多相电感,OCL 300 nH,DCR 低到 0.23 mOhm。

    • Typical use: 服务器多相 VRM、高端 GPU 供电.
    • H 系列是 CL 系列里 DCR 最低的一档,适合对效率敏感的场合。
    • Data sheet 4313; test conditions 1 MHz / 0.1 Vrms, +25 °C unless stated.

    Isat marks where the part leaves its inductive region. At 25 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 4 phases is the common configuration for a mid-power VRM. The phase count is set by the converter, not by the inductor - what matters here is that this part is the 4-phase variant with the matching pinout and DCR.

    Frequently Asked Questions

    Can I use fewer phases than the part number?
    No. The part number fixes the phase count and the pinout that goes with it.

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    What does the phase count mean?
    The number of independent windings sharing the same footprint. More phases means lower current per phase, lower copper loss and better ripple cancellation.

    Design note: use the full-load inductance and the hot-case
    DCR for the loss budget, and check the layout keeps each phase current loop closed.

    Mechanical Dimensions

    eaton-clh1110-multi-phase-inductor-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.