| Parameter | Value |
|---|---|
| Orderable part number | CLH1110R1-5-R050-R |
| Number of phases | 5 |
| Rated inductance per phase | 50 nH ±20% |
| Open circuit inductance (OCL) | 300 nH typical / 240 nH minimum |
| Full load inductance (FLL) | 200 nH minimum |
| DC resistance (DCR) | 0.23 mOhm |
| Rated current per phase | 25 A |
| Peak current per phase | 140 A |
| Package | CLH1110 footprint (see drawing) |
| Packaging | TR - tape and reel |
| RoHS | Compliant (-R suffix) |
The 25 A per phase rating is set by the winding and the core, not by the load. Design the converter so every phase shares the current evenly; an unbalanced phase reaches its limit long before the average current does.
DCR 0.23 mOhm at 20 °C is the number that sets efficiency. At 25 A per phase the winding loss is 0.1 W per phase; add the core loss and the phase count to get the total inductor loss in the converter.
CLH1110R1 是 R1 版 50 nH 多相电感,OCL 300 nH,DCR 低到 0.23 mOhm。
Isat marks where the part leaves its inductive region. At 25 A the inductance has already dropped well below its open-circuit value, so a design that runs close to that point trades ripple control for headroom. 5 phases is a high-current configuration. Per-phase current is low enough that copper loss stays small even with 25 A in each winding, which is the whole point of going to this many phases.
Which inductance should I use?
The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.
What is Isat?
The current at which the inductance starts to fall away. It is a magnetic limit, not a thermal one, and it is the point at which ripple control starts to go.
Which inductance should I use?
The rated inductance per phase, not the OCL. OCL is measured at zero bias; FLL is what the part has at rated current and it is the number the ripple calculation needs.
Design note: use the full-load inductance and the hot-case
DCR for the loss budget, and check the layout keeps each phase current loop closed.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd