Eaton CMS1-10-R Common-Mode Inductor, 73.7 uH OCL
Eaton CMS1-10-R Common-Mode Inductor, 73.7 uH OCL

Eaton CMS1-10-R Common-Mode Inductor, 73.7 uH OCL

Share
Eaton CMS1-10-R: 73.7 uH common-mode inductor, 1.65 A Irms, 0.048 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS1-10-R Common-Mode Inductor, 73.7 uH OCL

    CMS1-10-R: common-mode choke, OCL 73.7 uH minimum, 1.65 A Irms, leakage 0.81 uH.

    Product Specifications

    ParameterValue
    Orderable part numberCMS1-10-R
    Open circuit inductance (OCL)73.7 uH minimum, (1-2) & (4-3)
    I rms (max)1.65 A
    DCR typical @ 20 °C (1-2)0.048 ohm
    DCR typical @ 20 °C (4-3)0.048 ohm
    Leakage inductance typ0.81 uH
    Interwinding capacitance typ2.8 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    Differential mode is not affected in theory, but DCR is real: every milliohm is a voltage drop and a bit of heat in the signal path, and on a low-voltage rail that matters.

    Interwinding capacitance is the mechanism behind the high-frequency behaviour: above the capacitance the choke stops blocking and starts passing. Leakage inductance is the part of the inductance that escapes the core and does not help. 73.7 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 1.65 A Irms rating is not the thing limiting the design.

    Where This Series Fits

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 1.65 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.048 ohm of DCR the winding loss at that current is 0.13 W. CMS1 is the smallest of the three CMS footprints

    Frequently Asked Questions

    Does it affect my signal?
    Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.

    Is this part RoHS compliant?
    Yes - the -R suffix denotes the RoHS build.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.