| Parameter | Value |
|---|---|
| Orderable part number | CMS2-0-R |
| I rms (max) | 6 A |
| Open circuit inductance (OCL) | 14 uH minimum, (1-2) & (4-3) |
| DCR typical @ 20 °C (1-2) | 0.004 ohm |
| DCR typical @ 20 °C (4-3) | 0.004 ohm |
| Leakage inductance typ | 0.13 uH |
| Interwinding capacitance typ | 1.7 pF |
| Package | CMS series, surface mount |
| Operating temperature | 160 °C maximum |
| RoHS | Compliant (-R suffix) |
A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.
Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 14 uH puts CMS2-0-R in the low-inductance class of the CMS range. These are the parts for fast-switching nodes where you want a stiff choke close to the source, not a big energy-storage element further downstream.
CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。
The 14 uH of common-mode inductance is what blocks the noise; the 0.13 uH of leakage inductance is what gets past, and the 1.7 pF of interwinding capacitance is what couples across the windings at high frequency. CMS2 is the mid-size CMS footprint
What is the operating temperature?
The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.
Can I put it on a power line?
Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.
What is the operating temperature?
The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.
Design note: pick the choke by impedance at the noise
frequency, then confirm DCR and rated current against the signal or the rail.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd