| Parameter | Value |
|---|---|
| Orderable part number | CMS2-1-R |
| I rms (max) | 5.35 A |
| Open circuit inductance (OCL) | 25 uH minimum, (1-2) & (4-3) |
| DCR typical @ 20 °C (1-2) | 0.005 ohm |
| DCR typical @ 20 °C (4-3) | 0.005 ohm |
| Leakage inductance typ | 0.22 uH |
| Interwinding capacitance typ | 2 pF |
| Package | CMS series, surface mount |
| Operating temperature | 160 °C maximum |
| RoHS | Compliant (-R suffix) |
Differential mode is not affected in theory, but DCR is real: every milliohm is a voltage drop and a bit of heat in the signal path, and on a low-voltage rail that matters.
Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 25 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 5.35 A Irms rating is not the thing limiting the design.
CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。
The 25 uH of common-mode inductance is what blocks the noise; the 0.22 uH of leakage inductance is what gets past, and the 2 pF of interwinding capacitance is what couples across the windings at high frequency. CMS2 is the mid-size CMS footprint
Is this part RoHS compliant?
Yes - the -R suffix denotes the RoHS build.
What is the operating temperature?
The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.
Is this part RoHS compliant?
Yes - the -R suffix denotes the RoHS build.
Design note: pick the choke by impedance at the noise
frequency, then confirm DCR and rated current against the signal or the rail.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd