Eaton CMS2-14-R Common-Mode Noise Suppressor, 1340 uH
Eaton CMS2-14-R Common-Mode Noise Suppressor, 1340 uH

Eaton CMS2-14-R Common-Mode Noise Suppressor, 1340 uH

Share
Eaton CMS2-14-R: 1340 uH common-mode inductor, 0.5 A Irms, 0.62 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS2-14-R Common-Mode Noise Suppressor, 1340 uH

    CMS2-14-R at a glance: 1340 uH common-mode inductor, 0.5 A Irms, 0.62 ohm DCR, surface mount.

    Product Specifications

    ParameterValue
    Orderable part numberCMS2-14-R
    Open circuit inductance (OCL)1340 uH minimum, (1-2) & (4-3)
    I rms (max)0.5 A
    DCR typical @ 20 °C (1-2)0.62 ohm
    DCR typical @ 20 °C (4-3)0.62 ohm
    Leakage inductance typ9 uH
    Interwinding capacitance typ5.4 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.

    Interwinding capacitance is the mechanism behind the high-frequency behaviour: above the capacitance the choke stops blocking and starts passing. Leakage inductance is the part of the inductance that escapes the core and does not help. 1340 uH is a high-inductance part with a correspondingly low 0.5 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Where This Series Fits

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 0.5 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.62 ohm of DCR the winding loss at that current is 0.15 W. CMS2 is the mid-size CMS footprint

    Frequently Asked Questions

    What impedance should I pick?
    The one that gives the attenuation you need at the noise frequency of your circuit, then check that the DCR is acceptable on the signal.

    What impedance should I pick?
    The one that gives the attenuation you need at the noise frequency of your circuit, then check that the DCR is acceptable on the signal.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products