| Parameter | Value |
|---|---|
| Orderable part number | CMS2-5-R |
| Open circuit inductance (OCL) | 160 uH minimum, (1-2) & (4-3) |
| I rms (max) | 2.3 A |
| DCR typical @ 20 °C (1-2) | 0.029 ohm |
| DCR typical @ 20 °C (4-3) | 0.029 ohm |
| Leakage inductance typ | 1.25 uH |
| Interwinding capacitance typ | 3.1 pF |
| Package | CMS series, surface mount |
| Operating temperature | 160 °C maximum |
| RoHS | Compliant (-R suffix) |
The impedance figure is measured across the winding pair, which is exactly the common-mode path. That is why these parts are picked by impedance at the noise frequency rather than by inductance.
Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 160 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 2.3 A Irms rating is not the thing limiting the design.
CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。
Irms 2.3 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.029 ohm of DCR the winding loss at that current is 0.15 W. CMS2 is the mid-size CMS footprint
Does it affect my signal?
Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.
Why are there two DCR values?
The CMS series specifies each winding separately, measured between (1-2) and between (4-3).
Is this part RoHS compliant?
Yes - the -R suffix denotes the RoHS build.
Design note: pick the choke by impedance at the noise
frequency, then confirm DCR and rated current against the signal or the rail.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd