Eaton CMS2-7-R Common-Mode Inductor, 270 uH OCL
Eaton CMS2-7-R Common-Mode Inductor, 270 uH OCL

Eaton CMS2-7-R Common-Mode Inductor, 270 uH OCL

Share
Eaton CMS2-7-R: 270 uH common-mode inductor, 1.6 A Irms, 0.06 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS2-7-R Common-Mode Inductor, 270 uH OCL

    CMS2-7-R at a glance: 270 uH common-mode inductor, 1.6 A Irms, 0.06 ohm DCR, surface mount.

    Product Specifications

    ParameterValue
    Orderable part numberCMS2-7-R
    I rms (max)1.6 A
    Open circuit inductance (OCL)270 uH minimum, (1-2) & (4-3)
    DCR typical @ 20 °C (1-2)0.06 ohm
    DCR typical @ 20 °C (4-3)0.06 ohm
    Leakage inductance typ2 uH
    Interwinding capacitance typ3.6 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    Differential mode is not affected in theory, but DCR is real: every milliohm is a voltage drop and a bit of heat in the signal path, and on a low-voltage rail that matters.

    Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 270 uH is a high-inductance part with a correspondingly low 1.6 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Series Positioning

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    The 270 uH of common-mode inductance is what blocks the noise; the 2 uH of leakage inductance is what gets past, and the 3.6 pF of interwinding capacitance is what couples across the windings at high frequency. CMS2 is the mid-size CMS footprint

    Frequently Asked Questions

    Why are there two DCR values?
    The CMS series specifies each winding separately, measured between (1-2) and between (4-3).

    Is this part RoHS compliant?
    Yes - the -R suffix denotes the RoHS build.

    What is the operating temperature?
    The CMS series is rated to 160 °C maximum, with inductance values sustained up to that temperature.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products