Eaton CMS3-1-R Common-Mode Inductor, 28 uH OCL
Eaton CMS3-1-R Common-Mode Inductor, 28 uH OCL

Eaton CMS3-1-R Common-Mode Inductor, 28 uH OCL

Share
Eaton CMS3-1-R: 28 uH common-mode inductor, 5.7 A Irms, 0.005 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS3-1-R Common-Mode Inductor, 28 uH OCL

    CMS3-1-R: common-mode choke, OCL 28 uH minimum, 5.7 A Irms, leakage 0.31 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCMS3-1-R
    I rms (max)5.7 A
    Open circuit inductance (OCL)28 uH minimum, (1-2) & (4-3)
    DCR typical @ 20 °C (1-2)0.005 ohm
    DCR typical @ 20 °C (4-3)0.005 ohm
    Leakage inductance typ0.31 uH
    Interwinding capacitance typ2.8 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The impedance figure is measured across the winding pair, which is exactly the common-mode path. That is why these parts are picked by impedance at the noise frequency rather than by inductance.

    Impedance rolls off with frequency and with bias, so the value on the data sheet is a starting point rather than a guarantee. Model the network, then measure. 28 uH is the working middle of the CMS range: enough inductance to hold down the ripple on a rail, small enough that the 5.7 A Irms rating is not the thing limiting the design.

    Series Positioning

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 5.7 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.005 ohm of DCR the winding loss at that current is 0.16 W. CMS3 is the largest CMS footprint, with the lowest DCR of the three

    Frequently Asked Questions

    Does it affect my signal?
    Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.

    Does it affect my signal?
    Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.

    Is this part RoHS compliant?
    Yes - the -R suffix denotes the RoHS build.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.