Eaton CMS3-12-R Common-Mode Noise Suppressor, 790 uH
Eaton CMS3-12-R Common-Mode Noise Suppressor, 790 uH

Eaton CMS3-12-R Common-Mode Noise Suppressor, 790 uH

Share
Eaton CMS3-12-R: 790 uH common-mode inductor, 1.05 A Irms, 0.145 ohm DCR, surface mount.
    • Product Details
    • Download

    Eaton CMS3-12-R Common-Mode Noise Suppressor, 790 uH

    CMS3-12-R: common-mode choke, OCL 790 uH minimum, 1.05 A Irms, leakage 6.1 uH.

    Product Specifications

    ParameterValue
    Orderable part numberCMS3-12-R
    I rms (max)1.05 A
    Open circuit inductance (OCL)790 uH minimum, (1-2) & (4-3)
    DCR typical @ 20 °C (1-2)0.145 ohm
    DCR typical @ 20 °C (4-3)0.145 ohm
    Leakage inductance typ6.1 uH
    Interwinding capacitance typ5.35 pF
    PackageCMS series, surface mount
    Operating temperature160 °C maximum
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    A common-mode choke puts the same current through both windings in the same direction, so the differential signal passes through untouched while the common-mode noise sees the full impedance. It is the cheapest way to bring a switching node inside the emissions limit.

    For a DC-DC output filter this is the part that decides whether the noise stays inside the conducted limits, and how much margin the design keeps at the top of the load step. 790 uH is a high-inductance part with a correspondingly low 1.05 A Irms. The trade is deliberate - you give up current capability to get attenuation down low in the band where the noise actually lives.

    Series Positioning

    CMS 是贴片共模电感,CMS1 / CMS2 / CMS3 三个尺寸系列,4.5 uH 到 1310 uH。

    • Typical use: 开关电源输出滤波、DC-DC 共模抑制、EMI 整改.
    • CMS 的 OCL 是在 (1-2) 与 (4-3) 两组绕组上测的最小值,实际应用中两根线都要接对绕组。
    • Data sheet 4313.

    Irms 1.05 A is the thermal limit - a 40 °C temperature rise at 85 °C ambient. With 0.145 ohm of DCR the winding loss at that current is 0.16 W. CMS3 is the largest CMS footprint, with the lowest DCR of the three

    Frequently Asked Questions

    Is this part RoHS compliant?
    Yes - the -R suffix denotes the RoHS build.

    Can I put it on a power line?
    Only if the rated current covers the line. CMS is a signal-level series - for amps of current look at CMLA or a larger package.

    Does it affect my signal?
    Only through DCR and the small amount of leakage inductance. The differential signal is not filtered by design.

    Design note: pick the choke by impedance at the noise
    frequency, then confirm DCR and rated current against the signal or the rail.

    Mechanical Dimensions

    eaton-cms-common-mode-inductors-surface-mount-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd