Eaton CMT1-2-R - 49 mH 0.88 A Common Mode Choke
Eaton CMT1-2-R - 49 mH 0.88 A Common Mode Choke

Eaton CMT1-2-R - 49 mH 0.88 A Common Mode Choke

Share
Eaton CMT1-2-R: Through-Hole Common Mode Choke, 49 mH, 0.88 A, DCR 850 mOhm.
    • Product Details
    • Download

    Eaton CMT1-2-R - 49 mH 0.88 A Common Mode Choke

    Discontinued series. Eaton marked CMT discontinued effective 1 March 2016, or while inventory lasts. It is listed here as a service part for existing designs - specify a current production common-mode choke for new work.
    CMT1-2-R at a glance: through-hole common-mode choke, 49 mH per winding, 0.88 A rms, DCR 850 mOhm per winding.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCMT1-2-R
    Open circuit inductance (1-2), minimum49 mH
    Open circuit inductance (4-3), minimum49 mH
    Irms, maximum0.88 A
    DCR typical @ 20 °C (1-2)850 mOhm
    DCR typical @ 20 °C (4-3)850 mOhm
    MountingThrough-hole, 4 pins
    FlammabilityUL94V-0
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    The Figures Explained

    This is a through-hole off-line common-mode choke: two windings on one ferrite toroid, attenuation up to 68 dB, and inductance values that put the corner frequency well below the switching fundamental.

    The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.

    The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.

    Series Positioning

    CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.

    • Typical applications: Off-line power supplies, EMI filters, AC input of switching regulators, DC-DC converters, computer/TV/audio equipment.
    • Eaton marked this series discontinued effective 1 March 2016 or while inventory lasts - treat it as a service part for existing designs, not a new-design choice.
    • Data sheet 4312.

    Sizing It Into a Design

    49 mH sits at the high-inductance end of the range, and the trade at that point is explicit: 850 mOhm of DCR against - A of saturation headroom.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What is the isolation like?
    The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.

    Is this series still available?
    Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.

    What is the isolation like?
    The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.

    Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

    Mechanical Dimensions

    eaton-cmt-common-mode-inductors-through-hole-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.