Eaton CMT1-3-R Off-Line Common Mode Choke 28 mH
Eaton CMT1-3-R Off-Line Common Mode Choke 28 mH

Eaton CMT1-3-R Off-Line Common Mode Choke 28 mH

Share
Eaton CMT1-3-R: Through-Hole Common Mode Choke, 28 mH, 1.13 A, DCR 500 mOhm.
    • Product Details
    • Download

    Eaton CMT1-3-R Off-Line Common Mode Choke 28 mH

    Discontinued series. Eaton marked CMT discontinued effective 1 March 2016, or while inventory lasts. It is listed here as a service part for existing designs - specify a current production common-mode choke for new work.
    CMT1-3-R at a glance: through-hole common-mode choke, 28 mH per winding, 1.13 A rms, DCR 500 mOhm per winding.

    Key Specifications

    ParameterValue
    Orderable part numberCMT1-3-R
    Open circuit inductance (1-2), minimum28 mH
    Open circuit inductance (4-3), minimum28 mH
    Irms, maximum1.13 A
    DCR typical @ 20 °C (1-2)500 mOhm
    DCR typical @ 20 °C (4-3)500 mOhm
    MountingThrough-hole, 4 pins
    FlammabilityUL94V-0
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    The CMT sits between the inlet and the bridge rectifier. Differential current cancels in the core; common-mode noise - the kind that returns through earth - has to push both windings in the same direction and is blocked by the full inductance.

    The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.

    The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.

    Series Positioning

    CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.

    • Typical applications: Off-line power supplies, EMI filters, AC input of switching regulators, DC-DC converters, computer/TV/audio equipment.
    • Eaton marked this series discontinued effective 1 March 2016 or while inventory lasts - treat it as a service part for existing designs, not a new-design choice.
    • Data sheet 4312.

    Design Notes

    At 28 mH this part is at the high-inductance end of the family. The winding that produces that inductance is also what sets the 500 mOhm DCR - more turns, thinner wire, more resistance.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What is the isolation like?
    The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.

    Can I use it on a DC line?
    Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.

    Can I use it on a DC line?
    Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.

    Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

    Mechanical Dimensions

    eaton-cmt-common-mode-inductors-through-hole-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message