| Parameter | Value |
|---|---|
| Orderable part number | CMT1-4-R |
| Open circuit inductance (1-2), minimum | 21 mH |
| Open circuit inductance (4-3), minimum | 21 mH |
| Irms, maximum | 1.37 A |
| DCR typical @ 20 °C (1-2) | 350 mOhm |
| DCR typical @ 20 °C (4-3) | 350 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
Off-line supplies need a choke that will take the full AC line current without saturating, and still present a high impedance to the noise that tries to leave through the mains lead. That is the CMT.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
At 21 mH this part is at the high-inductance end of the family. The winding that produces that inductance is also what sets the 350 mOhm DCR - more turns, thinner wire, more resistance.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What is the isolation like?
The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.
Does it filter differential noise?
Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.
Why is there a separate OCL for each winding?
The two windings are measured separately, (1-2) and (4-3). A mismatch between them means an asymmetry in the differential impedance, so both are specified.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.