| Parameter | Value |
|---|---|
| Orderable part number | CMT1-5-R |
| Open circuit inductance (1-2), minimum | 13 mH |
| Open circuit inductance (4-3), minimum | 13 mH |
| Irms, maximum | 1.76 A |
| DCR typical @ 20 °C (1-2) | 200 mOhm |
| DCR typical @ 20 °C (4-3) | 200 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
Off-line supplies need a choke that will take the full AC line current without saturating, and still present a high impedance to the noise that tries to leave through the mains lead. That is the CMT.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
At 13 mH this part is in the middle of the range of the family. The winding that produces that inductance is also what sets the 200 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Why is there a separate OCL for each winding?
The two windings are measured separately, (1-2) and (4-3). A mismatch between them means an asymmetry in the differential impedance, so both are specified.
Is this series still available?
Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.
Does it filter differential noise?
Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd