Eaton CMT1-6-R: Through-Hole Common Mode Choke, 7.5 mH, 2.27 A, DCR 130 mOhm.
    • Product Details
    • Download

    Eaton CMT1-6-R - 7.5 mH 2.27 A Common Mode Choke

    Discontinued series. Eaton marked CMT discontinued effective 1 March 2016, or while inventory lasts. It is listed here as a service part for existing designs - specify a current production common-mode choke for new work.
    CMT1-6-R at a glance: through-hole common-mode choke, 7.5 mH per winding, 2.27 A rms, DCR 130 mOhm per winding.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCMT1-6-R
    Open circuit inductance (1-2), minimum7.5 mH
    Open circuit inductance (4-3), minimum7.5 mH
    Irms, maximum2.27 A
    DCR typical @ 20 °C (1-2)130 mOhm
    DCR typical @ 20 °C (4-3)130 mOhm
    MountingThrough-hole, 4 pins
    FlammabilityUL94V-0
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    Off-line supplies need a choke that will take the full AC line current without saturating, and still present a high impedance to the noise that tries to leave through the mains lead. That is the CMT.

    The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.

    The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.

    Where This Series Fits

    CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.

    • Typical applications: Off-line power supplies, EMI filters, AC input of switching regulators, DC-DC converters, computer/TV/audio equipment.
    • Eaton marked this series discontinued effective 1 March 2016 or while inventory lasts - treat it as a service part for existing designs, not a new-design choice.
    • Data sheet 4312.

    Sizing and Layout Notes

    At 7.5 mH this part is in the middle of the range of the family. The winding that produces that inductance is also what sets the 130 mOhm DCR - more turns, thinner wire, more resistance.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Does it filter differential noise?
    Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.

    Can I use it on a DC line?
    Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.

    What is the isolation like?
    The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.

    Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.