| Parameter | Value |
|---|---|
| Orderable part number | CMT2-2-R |
| Open circuit inductance (1-2), minimum | 20 mH |
| Open circuit inductance (4-3), minimum | 20 mH |
| Irms, maximum | 1.95 A |
| DCR typical @ 20 °C (1-2) | 220 mOhm |
| DCR typical @ 20 °C (4-3) | 220 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
Off-line supplies need a choke that will take the full AC line current without saturating, and still present a high impedance to the noise that tries to leave through the mains lead. That is the CMT.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
20 mH sits at the high-inductance end of the range, and the trade at that point is explicit: 220 mOhm of DCR against - A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the current rating based on?
The RMS line current at the rated temperature rise. Inrush and fault current are separate questions and are not covered by that number.
Is this series still available?
Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.
What is the isolation like?
The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd