| Parameter | Value |
|---|---|
| Orderable part number | CMT2-3-R |
| Open circuit inductance (1-2), minimum | 12 mH |
| Open circuit inductance (4-3), minimum | 12 mH |
| Irms, maximum | 2.45 A |
| DCR typical @ 20 °C (1-2) | 135 mOhm |
| DCR typical @ 20 °C (4-3) | 135 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
A common-mode choke on the AC input works because the mains current flows in opposite directions through the two windings, so the signal sees almost nothing while the common-mode noise sees the full impedance. It is the first stage of nearly every off-line filter.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
Choose 12 mH when the ripple target is in the middle of the range of the design window: the DCR stays at 135 mOhm and the saturation limit at - A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Why is there a separate OCL for each winding?
The two windings are measured separately, (1-2) and (4-3). A mismatch between them means an asymmetry in the differential impedance, so both are specified.
Why is there a separate OCL for each winding?
The two windings are measured separately, (1-2) and (4-3). A mismatch between them means an asymmetry in the differential impedance, so both are specified.
Why is there a separate OCL for each winding?
The two windings are measured separately, (1-2) and (4-3). A mismatch between them means an asymmetry in the differential impedance, so both are specified.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd