Eaton CMT2-4-R - 8 mH 2.8 A Common Mode Choke
Eaton CMT2-4-R - 8 mH 2.8 A Common Mode Choke

Eaton CMT2-4-R - 8 mH 2.8 A Common Mode Choke

Share
Eaton CMT2-4-R: Through-Hole Common Mode Choke, 8 mH, 2.8 A, DCR 100 mOhm.
    • Product Details
    • Download

    Eaton CMT2-4-R - 8 mH 2.8 A Common Mode Choke

    Discontinued series. Eaton marked CMT discontinued effective 1 March 2016, or while inventory lasts. It is listed here as a service part for existing designs - specify a current production common-mode choke for new work.
    CMT2-4-R at a glance: through-hole common-mode choke, 8 mH per winding, 2.8 A rms, DCR 100 mOhm per winding.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCMT2-4-R
    Open circuit inductance (1-2), minimum8 mH
    Open circuit inductance (4-3), minimum8 mH
    Irms, maximum2.8 A
    DCR typical @ 20 °C (1-2)100 mOhm
    DCR typical @ 20 °C (4-3)100 mOhm
    MountingThrough-hole, 4 pins
    FlammabilityUL94V-0
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    How to Read These Ratings

    A common-mode choke on the AC input works because the mains current flows in opposite directions through the two windings, so the signal sees almost nothing while the common-mode noise sees the full impedance. It is the first stage of nearly every off-line filter.

    The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.

    The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.

    Positioning in the Range

    CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.

    • Typical applications: Off-line power supplies, EMI filters, AC input of switching regulators, DC-DC converters, computer/TV/audio equipment.
    • Eaton marked this series discontinued effective 1 March 2016 or while inventory lasts - treat it as a service part for existing designs, not a new-design choice.
    • Data sheet 4312.

    Sizing and Layout Notes

    8 mH is in the middle of the range of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Can I use it on a DC line?
    Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.

    What is the current rating based on?
    The RMS line current at the rated temperature rise. Inrush and fault current are separate questions and are not covered by that number.

    Is this series still available?
    Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.

    Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

    Mechanical Dimensions

    eaton-cmt-common-mode-inductors-through-hole-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message