| Parameter | Value |
|---|---|
| Orderable part number | CMT2-8-R |
| Open circuit inductance (1-2), minimum | 2.4 mH |
| Open circuit inductance (4-3), minimum | 2.4 mH |
| Irms, maximum | 4.75 A |
| DCR typical @ 20 °C (1-2) | 37 mOhm |
| DCR typical @ 20 °C (4-3) | 37 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
The CMT sits between the inlet and the bridge rectifier. Differential current cancels in the core; common-mode noise - the kind that returns through earth - has to push both windings in the same direction and is blocked by the full inductance.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
Choose 2.4 mH when the ripple target is at the low-inductance end of the design window: the DCR stays at 37 mOhm and the saturation limit at - A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Does it filter differential noise?
Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.
Can I use it on a DC line?
Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.
Why is there a separate OCL for each winding?
The two windings are measured separately, (1-2) and (4-3). A mismatch between them means an asymmetry in the differential impedance, so both are specified.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.