| Parameter | Value |
|---|---|
| Orderable part number | CMT2-9-R |
| Open circuit inductance (1-2), minimum | 2 mH |
| Open circuit inductance (4-3), minimum | 2 mH |
| Irms, maximum | 5.45 A |
| DCR typical @ 20 °C (1-2) | 28 mOhm |
| DCR typical @ 20 °C (4-3) | 28 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
A common-mode choke on the AC input works because the mains current flows in opposite directions through the two windings, so the signal sees almost nothing while the common-mode noise sees the full impedance. It is the first stage of nearly every off-line filter.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
2 mH is at the low-inductance end of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
What is the isolation like?
The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.
Does it filter differential noise?
Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.
Is this series still available?
Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd