| Parameter | Value |
|---|---|
| Orderable part number | CMT3-5-R |
| Open circuit inductance (1-2), minimum | 0.92 mH |
| Open circuit inductance (4-3), minimum | 0.92 mH |
| Irms, maximum | 5 A |
| DCR typical @ 20 °C (1-2) | 21 mOhm |
| DCR typical @ 20 °C (4-3) | 21 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
This is a through-hole off-line common-mode choke: two windings on one ferrite toroid, attenuation up to 68 dB, and inductance values that put the corner frequency well below the switching fundamental.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
At 0.92 mH this part is at the low-inductance end of the family. The winding that produces that inductance is also what sets the 21 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Can I use it on a DC line?
Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.
Does it filter differential noise?
Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.
What is the isolation like?
The two windings share a core and are not a safety barrier - the insulation is functional, not reinforced.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd