| Parameter | Value |
|---|---|
| Orderable part number | CMT4-2-R |
| Open circuit inductance (1-2), minimum | 3.5 mH |
| Open circuit inductance (4-3), minimum | 3.5 mH |
| Irms, maximum | 2.6 A |
| DCR typical @ 20 °C (1-2) | 80 mOhm |
| DCR typical @ 20 °C (4-3) | 80 mOhm |
| Mounting | Through-hole, 4 pins |
| Flammability | UL94V-0 |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
The CMT sits between the inlet and the bridge rectifier. Differential current cancels in the core; common-mode noise - the kind that returns through earth - has to push both windings in the same direction and is blocked by the full inductance.
The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.
The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.
CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.
3.5 mH sits at the low-inductance end of the range, and the trade at that point is explicit: 80 mOhm of DCR against - A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Can I use it on a DC line?
Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.
Is this series still available?
Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.
What is the current rating based on?
The RMS line current at the rated temperature rise. Inrush and fault current are separate questions and are not covered by that number.
Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.