Eaton CMT4-3-R Common Mode Choke, 2.7 mH
Eaton CMT4-3-R Common Mode Choke, 2.7 mH

Eaton CMT4-3-R Common Mode Choke, 2.7 mH

Share
Eaton CMT4-3-R: Through-Hole Common Mode Choke, 2.7 mH, 3 A, DCR 55 mOhm.
    • Product Details
    • Download

    Eaton CMT4-3-R Common Mode Choke, 2.7 mH

    Discontinued series. Eaton marked CMT discontinued effective 1 March 2016, or while inventory lasts. It is listed here as a service part for existing designs - specify a current production common-mode choke for new work.
    CMT4-3-R at a glance: through-hole common-mode choke, 2.7 mH per winding, 3 A rms, DCR 55 mOhm per winding.

    Key Specifications

    ParameterValue
    Orderable part numberCMT4-3-R
    Open circuit inductance (1-2), minimum2.7 mH
    Open circuit inductance (4-3), minimum2.7 mH
    Irms, maximum3 A
    DCR typical @ 20 °C (1-2)55 mOhm
    DCR typical @ 20 °C (4-3)55 mOhm
    MountingThrough-hole, 4 pins
    FlammabilityUL94V-0
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    What the Numbers Mean

    The CMT sits between the inlet and the bridge rectifier. Differential current cancels in the core; common-mode noise - the kind that returns through earth - has to push both windings in the same direction and is blocked by the full inductance.

    The rated current is the RMS line current at the stated temperature rise, and the inductance is what remains under that current. A common-mode choke does not see differential DC, so saturation is not the usual failure mode here - heating is.

    The two windings are measured separately, (1-2) and (4-3), because a mismatch between them turns common-mode noise into differential noise - which the X-cap then has to absorb.

    Positioning in the Range

    CMT is a through-hole common-mode choke for the AC input of an off-line supply, with attenuation up to 68 dB and inductance from 0.53 mH to 66 mH. It sits ahead of the bridge and stops switching noise from travelling back down the mains lead.

    • Typical applications: Off-line power supplies, EMI filters, AC input of switching regulators, DC-DC converters, computer/TV/audio equipment.
    • Eaton marked this series discontinued effective 1 March 2016 or while inventory lasts - treat it as a service part for existing designs, not a new-design choice.
    • Data sheet 4312.

    Putting It to Work

    At 2.7 mH this part is at the low-inductance end of the family. The winding that produces that inductance is also what sets the 55 mOhm DCR - more turns, thinner wire, more resistance.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Is this series still available?
    Eaton lists CMT as discontinued effective March 2016 or while inventory lasts. Buy it as a service part for existing designs and plan a replacement for new ones.

    Does it filter differential noise?
    Not by design. The leakage inductance does provide a small differential impedance, but it is a by-product; use an X-capacitor and a differential choke for that.

    Can I use it on a DC line?
    Only if the DC current is well below the rated value - DC biases the core and eats the inductance. Common-mode chokes are specified for AC line current in opposing directions.

    Design note: rated for RMS line current, not inrush. The choke sits upstream of the bridge and downstream of the fuse - size the fuse first.

    Mechanical Dimensions

    eaton-cmt-common-mode-inductors-through-hole-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd