Eaton CPL-2-50TR-R 2-Phase Coupled Inductor, 50 nH/phase
Eaton CPL-2-50TR-R 2-Phase Coupled Inductor, 50 nH/phase

Eaton CPL-2-50TR-R 2-Phase Coupled Inductor, 50 nH/phase

Share
Eaton CPL-2-50TR-R: Multi-Phase Coupled Power Inductor, 50 nH per phase, 40 A, DCR 0.5 mOhm.
    • Product Details
    • Download

    Eaton CPL-2-50TR-R 2-Phase Coupled Inductor, 50 nH/phase

    CPL-2-50TR-R at a glance: 2-phase coupled inductor, 50 nH per phase, DCR 0.5 mOhm, 40 A rated per phase.

    Specification Table

    ParameterValue
    Orderable part numberCPL-2-50TR-R
    Number of phases2
    Rated inductance per phase50 nH/phase
    DCR nominal @ 25 °C0.5 mOhm
    DCR maximum @ 25 °C0.6 mOhm
    Rated current per phase40 A
    OCL, per pin pair365 nH typical / 365 nH minimum
    Magnetising inductance @ 5 Adc300 nH
    Frequency rangeup to 2 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The per-phase inductance is only half the story with a coupled part. The other half is the coupling - how much of one winding flux links the others, and what that does to the ripple and to the transient response.

    Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.

    The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.

    Positioning in the Range

    CPL is a 50 nH-per-phase coupled inductor built for Volterra and Maxim multiphase VPR controllers. The windings share one core, so the phases are magnetically coupled and the ripple partially cancels instead of adding.

    • Typical applications: Multiphase VRMs and Vcore regulators using Volterra or Maxim controllers, point-of-load converters.
    • Eaton specifies this family for exclusive use with those controllers - the coupling is part of the control loop, not an optional extra.
    • Data sheet 4362.

    Sizing and Layout Notes

    50 nH per phase is at the design point the controller expects of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What does "coupled" change electrically?
    The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.

    What is the magnetising inductance for?
    It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.

    What is the magnetising inductance for?
    It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.

    Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

    Mechanical Dimensions

    eaton-cpl-cpla-cple-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.