| Parameter | Value |
|---|---|
| Orderable part number | CPL-4-50TR-R |
| Number of phases | 4 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.5 mOhm |
| DCR maximum @ 25 °C | 0.6 mOhm |
| Rated current per phase | 40 A |
| OCL, per pin pair | 490 nH typical / 365 nH minimum |
| Magnetising inductance @ 5 Adc | 400 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
The per-phase inductance is only half the story with a coupled part. The other half is the coupling - how much of one winding flux links the others, and what that does to the ripple and to the transient response.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPL is a 50 nH-per-phase coupled inductor built for Volterra and Maxim multiphase VPR controllers. The windings share one core, so the phases are magnetically coupled and the ripple partially cancels instead of adding.
50 nH per phase sits at the design point the controller expects of the range, and the trade at that point is explicit: 0.5 mOhm of DCR against - A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Why is the rated inductance given per phase?
Because the windings are separate phases sharing a core. The per-phase value is what sets each phase current ripple.
What current does the rating refer to?
Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.
What is the magnetising inductance for?
It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.