| Parameter | Value |
|---|---|
| Orderable part number | CPL-5-50TR-R |
| Number of phases | 5 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.5 mOhm |
| DCR maximum @ 25 °C | 0.6 mOhm |
| Rated current per phase | 40 A |
| OCL, per pin pair | 490 nH typical / 365 nH minimum |
| Magnetising inductance @ 5 Adc | 400 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
The per-phase inductance is only half the story with a coupled part. The other half is the coupling - how much of one winding flux links the others, and what that does to the ripple and to the transient response.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPL is a 50 nH-per-phase coupled inductor built for Volterra and Maxim multiphase VPR controllers. The windings share one core, so the phases are magnetically coupled and the ripple partially cancels instead of adding.
At 50 nH per phase this part is at the design point the controller expects of the family. The winding that produces that inductance is also what sets the 0.5 mOhm DCR - more turns, thinner wire, more resistance.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
Are CPL, CPLA and CPLE interchangeable?
Electrically similar, mechanically different: CPLA adds acoustic dampening and CPLE uses a core optimised for light-load efficiency. Confirm with the reference design.
What current does the rating refer to?
Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.
What is the magnetising inductance for?
It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.