Eaton CPL-6-50TR-R 6-Phase Coupled Inductor, 50 nH/phase
Eaton CPL-6-50TR-R 6-Phase Coupled Inductor, 50 nH/phase

Eaton CPL-6-50TR-R 6-Phase Coupled Inductor, 50 nH/phase

Share
Eaton CPL-6-50TR-R: Multi-Phase Coupled Power Inductor, 50 nH per phase, 40 A, DCR 0.5 mOhm.
    • Product Details
    • Download

    Eaton CPL-6-50TR-R 6-Phase Coupled Inductor, 50 nH/phase

    CPL-6-50TR-R at a glance: 6-phase coupled inductor, 50 nH per phase, DCR 0.5 mOhm, 40 A rated per phase.

    Key Specifications

    ParameterValue
    Orderable part numberCPL-6-50TR-R
    Number of phases6
    Rated inductance per phase50 nH/phase
    DCR nominal @ 25 °C0.5 mOhm
    DCR maximum @ 25 °C0.6 mOhm
    Rated current per phase40 A
    OCL, per pin pair490 nH typical / 365 nH minimum
    Magnetising inductance @ 5 Adc400 nH
    Frequency rangeup to 2 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The per-phase inductance is only half the story with a coupled part. The other half is the coupling - how much of one winding flux links the others, and what that does to the ripple and to the transient response.

    The arithmetic is the usual one for coupled windings: parallel gives L/4 with 2x the current capability, series gives 4L with half. DCR follows the same rule - parallel halves the resistance, series doubles it.

    The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.

    What This Family Is For

    CPL is a 50 nH-per-phase coupled inductor built for Volterra and Maxim multiphase VPR controllers. The windings share one core, so the phases are magnetically coupled and the ripple partially cancels instead of adding.

    • Typical applications: Multiphase VRMs and Vcore regulators using Volterra or Maxim controllers, point-of-load converters.
    • Eaton specifies this family for exclusive use with those controllers - the coupling is part of the control loop, not an optional extra.
    • Data sheet 4362.

    Sizing and Layout Notes

    50 nH per phase sits at the design point the controller expects of the range, and the trade at that point is explicit: 0.5 mOhm of DCR against - A of saturation headroom.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    Are CPL, CPLA and CPLE interchangeable?
    Electrically similar, mechanically different: CPLA adds acoustic dampening and CPLE uses a core optimised for light-load efficiency. Confirm with the reference design.

    What is the magnetising inductance for?
    It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.

    What does "coupled" change electrically?
    The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.

    Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

    Mechanical Dimensions

    eaton-cpl-cpla-cple-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.