| Parameter | Value |
|---|---|
| Orderable part number | CPL2-2-50TR-R |
| Number of phases | 2 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.28 mOhm |
| Rated current per phase | 50 A |
| Peak current per phase | 80 A |
| OCL, per pin pair | 380 nH typical / 380 nH minimum |
| Magnetising inductance @ 5 Adc | 300 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
Coupling is the whole point of this family. Fifty nanohenries per phase, wound on a shared core, so that the ripple from one phase subtracts from its neighbours instead of adding. The result is a converter that can run at a lower switching frequency for the same output ripple.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPL2 is the low-core-loss 50 nH multiphase coupled inductor: same coupling idea as CPL, revised core for efficiency, rated to 50 A per phase with an 80 A peak.
Choose 50 nH per phase when the ripple target is at the design point the controller expects of the design window: the DCR stays at 0.28 mOhm and the saturation limit at 80 A leaves the transient room it needs.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Why is the rated inductance given per phase?
Because the windings are separate phases sharing a core. The per-phase value is what sets each phase current ripple.
Are CPL, CPLA and CPLE interchangeable?
Electrically similar, mechanically different: CPLA adds acoustic dampening and CPLE uses a core optimised for light-load efficiency. Confirm with the reference design.
What current does the rating refer to?
Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.