Eaton CPL2-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor
Eaton CPL2-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor

Eaton CPL2-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor

Share
Eaton CPL2-3-50TR-R: Multi-Phase Coupled Power Inductor, 50 nH per phase, 50 A, DCR 0.28 mOhm.
    • Product Details
    • Download

    Eaton CPL2-3-50TR-R - 3-Phase 50 nH/phase Coupled Inductor

    CPL2-3-50TR-R at a glance: 3-phase coupled inductor, 50 nH per phase, DCR 0.28 mOhm, 50 A rated per phase.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCPL2-3-50TR-R
    Number of phases3
    Rated inductance per phase50 nH/phase
    DCR nominal @ 25 °C0.28 mOhm
    Rated current per phase50 A
    Peak current per phase80 A
    OCL, per pin pair400 nH typical / 380 nH minimum
    Magnetising inductance @ 5 Adc300 nH
    Frequency rangeup to 2 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    The Figures Explained

    These parts are built for multiphase VRM controllers: the windings share flux, the phases are designed as a set, and the inductor is part of the control loop rather than a passive component at the output.

    Series mode is often mistaken for a way to get more current. It is the opposite - four times the inductance, half the saturation current, twice the DCR. Use it when you need inductance, not when you need amps.

    The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.

    Positioning in the Range

    CPL2 is the low-core-loss 50 nH multiphase coupled inductor: same coupling idea as CPL, revised core for efficiency, rated to 50 A per phase with an 80 A peak.

    • Typical applications: High-current multiphase VRMs, Volterra and Maxim VPR controllers, point-of-load.
    • DCR is quoted at ±10% here rather than the ±20% of the CPL family - the tolerance is tighter, the loss budget is not automatically better.
    • Data sheet 4357.

    Design Notes

    At 50 nH per phase this part is at the design point the controller expects of the family. The winding that produces that inductance is also what sets the 0.28 mOhm DCR - more turns, thinner wire, more resistance.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    Can I use it with any multiphase controller?
    No. Eaton specifies these families for Volterra or Maxim VPR devices, and the coupling is part of the reference design. Check the controller before you substitute.

    What is the magnetising inductance for?
    It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.

    Are CPL, CPLA and CPLE interchangeable?
    Electrically similar, mechanically different: CPLA adds acoustic dampening and CPLE uses a core optimised for light-load efficiency. Confirm with the reference design.

    Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

    Mechanical Dimensions

    eaton-cpl2-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.