| Parameter | Value |
|---|---|
| Orderable part number | CPL2-4-50TR-R |
| Number of phases | 4 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.28 mOhm |
| Rated current per phase | 50 A |
| Peak current per phase | 80 A |
| OCL, per pin pair | 400 nH typical / 380 nH minimum |
| Magnetising inductance @ 5 Adc | 300 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
These parts are built for multiphase VRM controllers: the windings share flux, the phases are designed as a set, and the inductor is part of the control loop rather than a passive component at the output.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPL2 is the low-core-loss 50 nH multiphase coupled inductor: same coupling idea as CPL, revised core for efficiency, rated to 50 A per phase with an 80 A peak.
Choose 50 nH per phase when the ripple target is at the design point the controller expects of the design window: the DCR stays at 0.28 mOhm and the saturation limit at 80 A leaves the transient room it needs.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What current does the rating refer to?
Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.
Why is the rated inductance given per phase?
Because the windings are separate phases sharing a core. The per-phase value is what sets each phase current ripple.
Can I use it with any multiphase controller?
No. Eaton specifies these families for Volterra or Maxim VPR devices, and the coupling is part of the reference design. Check the controller before you substitute.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.