Eaton CPLA-4-50TR-R 4-Phase VRM Inductor, 40 A
Eaton CPLA-4-50TR-R 4-Phase VRM Inductor, 40 A

Eaton CPLA-4-50TR-R 4-Phase VRM Inductor, 40 A

Share
Eaton CPLA-4-50TR-R: Multi-Phase Coupled Power Inductor, Acoustic Dampened, 50 nH per phase, 40 A, DCR 0.5 mOhm.
    • Product Details
    • Download

    Eaton CPLA-4-50TR-R 4-Phase VRM Inductor, 40 A

    CPLA-4-50TR-R at a glance: 4-phase coupled inductor, 50 nH per phase, DCR 0.5 mOhm, 40 A rated per phase.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCPLA-4-50TR-R
    Number of phases4
    Rated inductance per phase50 nH/phase
    DCR nominal @ 25 °C0.5 mOhm
    DCR maximum @ 25 °C0.6 mOhm
    Rated current per phase40 A
    OCL, per pin pair490 nH typical / 365 nH minimum
    Magnetising inductance @ 5 Adc400 nH
    Frequency rangeup to 2 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The per-phase inductance is only half the story with a coupled part. The other half is the coupling - how much of one winding flux links the others, and what that does to the ripple and to the transient response.

    Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.

    The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.

    Positioning in the Range

    CPLA is the acoustic-noise-damped version of the 50 nH CPL. Same electrical behaviour, different construction, so the magnetostriction that makes a coupled inductor sing at the switching frequency is suppressed.

    • Typical applications: Noise-sensitive multiphase VRMs, Vcore rails in equipment with acoustic limits.
    • CPLA is not electrically interchangeable with CPL for every controller - the dampening changes the mechanical build; confirm with the reference design.
    • Data sheet 4362.

    Putting It to Work

    50 nH per phase is at the design point the controller expects of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.

    The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.

    Frequently Asked Questions

    What does "coupled" change electrically?
    The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.

    What does "coupled" change electrically?
    The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.

    What current does the rating refer to?
    Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.

    Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

    Mechanical Dimensions

    eaton-cpl-cpla-cple-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.