| Parameter | Value |
|---|---|
| Orderable part number | CPLA-4-50TR-R |
| Number of phases | 4 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.5 mOhm |
| DCR maximum @ 25 °C | 0.6 mOhm |
| Rated current per phase | 40 A |
| OCL, per pin pair | 490 nH typical / 365 nH minimum |
| Magnetising inductance @ 5 Adc | 400 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
The per-phase inductance is only half the story with a coupled part. The other half is the coupling - how much of one winding flux links the others, and what that does to the ripple and to the transient response.
Coupled operation is where the part earns its keep: with the right duty cycle the two windings cancel part of the ripple, so the output capacitor sees less AC current and the converter can run at a lower switching frequency for the same ripple.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPLA is the acoustic-noise-damped version of the 50 nH CPL. Same electrical behaviour, different construction, so the magnetostriction that makes a coupled inductor sing at the switching frequency is suppressed.
50 nH per phase is at the design point the controller expects of what this series covers. Moving up in inductance costs DCR and saturation current; moving down buys both, at the price of ripple.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
What does "coupled" change electrically?
The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.
What does "coupled" change electrically?
The phase currents see a mutual term, so the effective ripple depends on how the phases are driven. In the intended controller the ripple cancels; outside it, it can add.
What current does the rating refer to?
Rated current per phase. The total the converter can deliver is that multiplied by the number of phases, subject to the thermal design of the board.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.