Eaton CPLE-2-50TR-R Multi-Phase Power Inductor 2 Phases
Eaton CPLE-2-50TR-R Multi-Phase Power Inductor 2 Phases

Eaton CPLE-2-50TR-R Multi-Phase Power Inductor 2 Phases

Share
Eaton CPLE-2-50TR-R: Multi-Phase Coupled Power Inductor, Light-Load Optimised, 50 nH per phase, 40 A, DCR 0.5 mOhm.
    • Product Details
    • Download

    Eaton CPLE-2-50TR-R Multi-Phase Power Inductor 2 Phases

    CPLE-2-50TR-R at a glance: 2-phase coupled inductor, 50 nH per phase, DCR 0.5 mOhm, 40 A rated per phase.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCPLE-2-50TR-R
    Number of phases2
    Rated inductance per phase50 nH/phase
    DCR nominal @ 25 °C0.5 mOhm
    DCR maximum @ 25 °C0.6 mOhm
    Rated current per phase40 A
    OCL, per pin pair365 nH typical / 365 nH minimum
    Magnetising inductance @ 5 Adc300 nH
    Frequency rangeup to 2 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    These parts are built for multiphase VRM controllers: the windings share flux, the phases are designed as a set, and the inductor is part of the control loop rather than a passive component at the output.

    In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.

    The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.

    Where This Series Fits

    CPLE uses a core material optimised for light-load efficiency: the same 50 nH per phase, but lower core loss when the converter is idling, which is where a server or a notebook spends most of its life.

    • Typical applications: Multiphase VRMs with light-load efficiency targets, Vcore rails, point-of-load.
    • The benefit shows up at light load; at full load the difference against CPL is small, so size for the load profile you actually have.
    • Data sheet 4362.

    Design Notes

    50 nH per phase sits at the design point the controller expects of the range, and the trade at that point is explicit: 0.5 mOhm of DCR against - A of saturation headroom.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    Why is the rated inductance given per phase?
    Because the windings are separate phases sharing a core. The per-phase value is what sets each phase current ripple.

    Can I use it with any multiphase controller?
    No. Eaton specifies these families for Volterra or Maxim VPR devices, and the coupling is part of the reference design. Check the controller before you substitute.

    Can I use it with any multiphase controller?
    No. Eaton specifies these families for Volterra or Maxim VPR devices, and the coupling is part of the reference design. Check the controller before you substitute.

    Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

    Mechanical Dimensions

    eaton-cpl-cpla-cple-multi-phase-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products