| Parameter | Value |
|---|---|
| Orderable part number | CPLE-3-50TR-R |
| Number of phases | 3 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.5 mOhm |
| DCR maximum @ 25 °C | 0.6 mOhm |
| Rated current per phase | 40 A |
| OCL, per pin pair | 490 nH typical / 365 nH minimum |
| Magnetising inductance @ 5 Adc | 400 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
Coupling is the whole point of this family. Fifty nanohenries per phase, wound on a shared core, so that the ripple from one phase subtracts from its neighbours instead of adding. The result is a converter that can run at a lower switching frequency for the same output ripple.
Series mode is often mistaken for a way to get more current. It is the opposite - four times the inductance, half the saturation current, twice the DCR. Use it when you need inductance, not when you need amps.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPLE uses a core material optimised for light-load efficiency: the same 50 nH per phase, but lower core loss when the converter is idling, which is where a server or a notebook spends most of its life.
At 50 nH per phase this part is at the design point the controller expects of the family. The winding that produces that inductance is also what sets the 0.5 mOhm DCR - more turns, thinner wire, more resistance.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
What is the magnetising inductance for?
It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.
What is the magnetising inductance for?
It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.
Are CPL, CPLA and CPLE interchangeable?
Electrically similar, mechanically different: CPLA adds acoustic dampening and CPLE uses a core optimised for light-load efficiency. Confirm with the reference design.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd