| Parameter | Value |
|---|---|
| Orderable part number | CPLE-5-50TR-R |
| Number of phases | 5 |
| Rated inductance per phase | 50 nH/phase |
| DCR nominal @ 25 °C | 0.5 mOhm |
| DCR maximum @ 25 °C | 0.6 mOhm |
| Rated current per phase | 40 A |
| OCL, per pin pair | 490 nH typical / 365 nH minimum |
| Magnetising inductance @ 5 Adc | 400 nH |
| Frequency range | up to 2 MHz |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| RoHS | Compliant (-R suffix) |
These parts are built for multiphase VRM controllers: the windings share flux, the phases are designed as a set, and the inductor is part of the control loop rather than a passive component at the output.
In parallel mode the two windings share the current and the DCR drops by half, which is why the parallel rating is roughly twice the single-winding rating rather than exactly twice: the thermal path is the same core.
The per-phase DCR is what sets the conduction loss, and the coupling is what sets the ripple. Neither number alone tells you whether the part will work in a given controller.
CPLE uses a core material optimised for light-load efficiency: the same 50 nH per phase, but lower core loss when the converter is idling, which is where a server or a notebook spends most of its life.
50 nH per phase sits at the design point the controller expects of the range, and the trade at that point is explicit: 0.5 mOhm of DCR against - A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the magnetising inductance for?
It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.
Why is the rated inductance given per phase?
Because the windings are separate phases sharing a core. The per-phase value is what sets each phase current ripple.
What is the magnetising inductance for?
It describes the flux that links all windings together, which is what governs the common-mode behaviour of the phase currents.
Design note: use the per-phase rated inductance, not the OCL, and confirm the controller is the one the family was characterised with.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.