Eaton CTX0.68-4P-R Toroid Power Inductor
Eaton CTX0.68-4P-R Toroid Power Inductor

Eaton CTX0.68-4P-R Toroid Power Inductor

Share
CTX0.68-4P-R: toroid power inductor, 0.76 uH.
    • Product Details
    • Download

    Eaton CTX0.68-4P-R Toroid Power Inductor

    CTX0.68-4P-R at a glance: toroid power inductor, 0.76 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCTX0.68-4P-R
    Inductance, parallel0.76 uH
    Inductance, series3.05 uH
    DC current, parallel7.2 A
    DC current, series3.6 A
    DCR, parallel maximum6 mOhm
    DCR, series maximum23 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    The ECONO-PAC and OCTA-PAC families are the same construction in different core grades: a toroid with two identical windings brought out to four pads, so one part covers two inductance ranges.

    Parallel gives 0.76 uH at 7.2 A; series gives 3.05 uH at 3.6 A. The inductance ratio is about 4.01 to 1, which is the turns-squared rule at work.

    Within the CTX0.68 family this is item 4 of 4 in the Eaton catalogue.

    What This Family Is For

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Can it be used as a transformer?
    Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.

    Can it be used as a transformer?
    Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message