| Parameter | Value |
|---|---|
| Orderable part number | CTX110652-R |
| Lamp power | 2.5 W |
| Primary inductance Lp | 43 uH |
| Turns ratio Ns/Np | 67 |
| DCR primary maximum | 220 mOhm |
| DCR secondary maximum | 285 Ohm |
| Primary voltage maximum | 20 V |
| Secondary voltage maximum | 1340 V |
| Secondary current maximum | 0.005 A rms |
| Primary voltage, abnormal | 30 V |
| Secondary voltage, abnormal | 2000 V |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | 0 C to +70 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4303 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data 4303; the package line above gives the body size where
the data sheet states it.
The tube needs roughly 1000 to 1500 V to strike and a few milliamps to run, so the secondary winding carries many turns of fine wire. That is why the secondary DCR is quoted in hundreds of ohms while the primary DCR is a fraction of an ohm.
A 67:1 ratio with 20 V across the primary puts 1340 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.
The rated 0.005 A rms into 1340 V is about 6.7 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.
Within the CTX110652 family this is item 1 of 1 in the Eaton catalogue.
The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.
What is the abnormal condition rating for?
It is the voltage the transformer withstands when the lamp does not strike or is removed. In that state the inverter runs open loop and the secondary voltage climbs until something breaks down, so the part has to survive it until the protection circuit trips.
Is the part isolated?
Yes, primary to secondary is isolated by the bobbin construction; the data sheet gives the isolation test voltage. That isolation is what keeps the lamp circuit separate from the low-voltage side.
Why is the secondary DCR so high?
The secondary has many turns of very fine wire to reach 1300 V or more. Resistance scales with turns and inversely with wire area, so a high-ratio secondary inevitably has tens or hundreds of ohms.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd