CTX2-2P-R: toroid power inductor, 2.18 uH.
    • Product Details
    • Download

    Eaton CTX2-2P-R ECONO-PAC / OCTA-PAC Inductor

    CTX2-2P-R at a glance: toroid power inductor, 2.18 uH.

    Electrical Specifications

    ParameterValue
    Orderable part numberCTX2-2P-R
    Inductance, parallel2.18 uH
    Inductance, series8.7 uH
    DC current, parallel3.9 A
    DC current, series1.95 A
    DCR, parallel maximum14 mOhm
    DCR, series maximum55 mOhm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    How to Read These Ratings

    A toroid wound on a distributed-gap core, with two windings that can be wired in parallel or in series. Parallel gives the low inductance and the high current; series gives four times the inductance at half the current. Both ratings are on the data sheet because both are legitimate ways to use the part.

    Parallel gives 2.18 uH at 3.9 A; series gives 8.7 uH at 1.95 A. The inductance ratio is about 3.99 to 1, which is the turns-squared rule at work.

    Within the CTX2 family this is item 2 of 4 in the Eaton catalogue.

    Positioning in the Range

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.

    Parallel or series – which do I use?
    Parallel for high current at low inductance, series for the opposite. The two windings are identical, so series connection quadruples the inductance and halves the current rating.