| Parameter | Value |
|---|---|
| Orderable part number | CTX210611-R |
| Lamp power | 6 W |
| Primary inductance Lp | 20 uH |
| Turns ratio Ns/Np | 125 |
| DCR primary maximum | 132 mOhm |
| DCR secondary maximum | 291 Ohm |
| Primary voltage maximum | 11 V |
| Secondary voltage maximum | 1340 V |
| Secondary current maximum | 0.011 A rms |
| Primary voltage, abnormal | 16 V |
| Secondary voltage, abnormal | 2000 V |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | 0 C to +70 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 4303 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data 4303; the package line above gives the body size where
the data sheet states it.
This is a surface-mount CCFL transformer in a potted case: ferrite core, split bobbin, secondary sectioned to keep the voltage stress manageable. The abnormal condition columns give the voltage the part survives when the tube fails to strike.
A 125:1 ratio with 11 V across the primary puts 1375 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.
The rated 0.011 A rms into 1340 V is about 14.7 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.
Within the CTX210611 family this is item 1 of 1 in the Eaton catalogue.
The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.
Why is the secondary DCR so high?
The secondary has many turns of very fine wire to reach 1300 V or more. Resistance scales with turns and inversely with wire area, so a high-ratio secondary inevitably has tens or hundreds of ohms.
Can I drive the tube from a different inverter?
Only if the turns ratio and the saturation current match. The transformer is part of the resonant tank; changing the ratio moves the operating point and can push the core into saturation.
Is the part isolated?
Yes, primary to secondary is isolated by the bobbin construction; the data sheet gives the isolation test voltage. That isolation is what keeps the lamp circuit separate from the low-voltage side.