Eaton CTX300-3P-R Toroid Inductor, Parallel 298 uH
Eaton CTX300-3P-R Toroid Inductor, Parallel 298 uH

Eaton CTX300-3P-R Toroid Inductor, Parallel 298 uH

Share
CTX300-3P-R: toroid power inductor, 298 uH.
    • Product Details
    • Download

    Eaton CTX300-3P-R Toroid Inductor, Parallel 298 uH

    CTX300-3P-R at a glance: toroid power inductor, 298 uH.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCTX300-3P-R
    Inductance, parallel298 uH
    Inductance, series1194 uH
    DC current, parallel0.5 A
    DC current, series0.25 A
    DCR, parallel maximum926 mOhm
    DCR, series maximum3.7 Ohm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A toroid wound on a distributed-gap core, with two windings that can be wired in parallel or in series. Parallel gives the low inductance and the high current; series gives four times the inductance at half the current. Both ratings are on the data sheet because both are legitimate ways to use the part.

    Parallel gives 298 uH at 0.5 A; series gives 1194 uH at 0.25 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX300 family this is item 3 of 4 in the Eaton catalogue.

    Positioning in the Range

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Why four times the inductance and not twice?
    Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.

    Can it be used as a transformer?
    Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.