Eaton CTX310407-R Lamp Inverter Transformer 86:1
Eaton CTX310407-R Lamp Inverter Transformer 86:1

Eaton CTX310407-R Lamp Inverter Transformer 86:1

Share
CTX310407-R: CCFL inverter transformer, 27 uH, 4 W, 86:1.
    • Product Details
    • Download

    Eaton CTX310407-R Lamp Inverter Transformer 86:1

    CTX310407-R at a glance: CCFL inverter transformer, 27 uH, 4 W, 86:1.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCTX310407-R
    Lamp power4 W
    Primary inductance Lp27 uH
    Turns ratio Ns/Np86
    DCR primary maximum160 mOhm
    DCR secondary maximum220 Ohm
    Primary voltage maximum15 V
    Secondary voltage maximum1340 V
    Secondary current maximum0.007 A rms
    Primary voltage, abnormal23 V
    Secondary voltage, abnormal2000 V
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature0 C to +70 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4303

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4303; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A CCFL inverter transformer drives a cold cathode fluorescent tube: the primary sees a few tens of volts from the Royer or push-pull stage, the secondary produces the strike voltage, and the turns ratio sets both. The numbers on this page are the design inputs for that stage, not marketing figures.

    A 86:1 ratio with 15 V across the primary puts 1290 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.

    The rated 0.007 A rms into 1340 V is about 9.38 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.

    Within the CTX310407 family this is item 1 of 1 in the Eaton catalogue.

    What This Family Is For

    The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.

    • The secondary runs at over 1 kV. Creepage, potting and the lead dress are part of the design, not details to fix later.
    • Typical applications: ccfl power supplies.
    • Design note: choose on turns ratio and abnormal voltage first, then check the lamp power against the Pout rating.

    Frequently Asked Questions

    What is the abnormal condition rating for?
    It is the voltage the transformer withstands when the lamp does not strike or is removed. In that state the inverter runs open loop and the secondary voltage climbs until something breaks down, so the part has to survive it until the protection circuit trips.

    Is the part isolated?
    Yes, primary to secondary is isolated by the bobbin construction; the data sheet gives the isolation test voltage. That isolation is what keeps the lamp circuit separate from the low-voltage side.

    Is the part isolated?
    Yes, primary to secondary is isolated by the bobbin construction; the data sheet gives the isolation test voltage. That isolation is what keeps the lamp circuit separate from the low-voltage side.