CTX410807-R: CCFL inverter transformer, 16 uH, 14 W, 86:1.
    • Product Details
    • Download

    Eaton CTX410807-R Lamp Inverter Transformer 86:1

    CTX410807-R at a glance: CCFL inverter transformer, 16 uH, 14 W, 86:1.

    Specification Table

    ParameterValue
    Orderable part numberCTX410807-R
    Lamp power14 W
    Primary inductance Lp16 uH
    Turns ratio Ns/Np86
    DCR primary maximum24 mOhm
    DCR secondary maximum272 Ohm
    Primary voltage maximum15 V
    Secondary voltage maximum1340 V
    Secondary current maximum0.03 A rms
    Primary voltage, abnormal23 V
    Secondary voltage, abnormal2000 V
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature0 C to +70 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4303

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data 4303; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A CCFL inverter transformer drives a cold cathode fluorescent tube: the primary sees a few tens of volts from the Royer or push-pull stage, the secondary produces the strike voltage, and the turns ratio sets both. The numbers on this page are the design inputs for that stage, not marketing figures.

    A 86:1 ratio with 15 V across the primary puts 1290 V on the secondary at full drive, against a tube strike requirement of roughly 1000 to 1500 V.

    The rated 0.03 A rms into 1340 V is about 40.2 VA of lamp power, which is why the secondary winding is the thermal limit rather than the core.

    Within the CTX410807 family this is item 1 of 1 in the Eaton catalogue.

    Where This Series Fits

    The CCFL range covers 2.5 W to 6 W lamps in two case sizes, with turns ratios from 50:1 to 100:1 and secondary voltages up to 2000 V under abnormal conditions.

    • The secondary runs at over 1 kV. Creepage, potting and the lead dress are part of the design, not details to fix later.
    • Typical applications: ccfl power supplies.
    • Design note: choose on turns ratio and abnormal voltage first, then check the lamp power against the Pout rating.

    Frequently Asked Questions

    Why is the secondary DCR so high?
    The secondary has many turns of very fine wire to reach 1300 V or more. Resistance scales with turns and inversely with wire area, so a high-ratio secondary inevitably has tens or hundreds of ohms.

    What is the abnormal condition rating for?
    It is the voltage the transformer withstands when the lamp does not strike or is removed. In that state the inverter runs open loop and the secondary voltage climbs until something breaks down, so the part has to survive it until the protection circuit trips.

    What does the Pout rating mean?
    It is the lamp power the part is designed for, which sets the core size and the wire gauge. Running a 2.5 W part at 6 W will overheat the winding even if the voltage rating is met.