| Parameter | Value |
|---|---|
| Orderable part number | CTX5-2P-R |
| Inductance, parallel | 4.9 uH |
| Inductance, series | 19.6 uH |
| DC current, parallel | 2.5 A |
| DC current, series | 1.25 A |
| DCR, parallel maximum | 32 mOhm |
| DCR, series maximum | 128 mOhm |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data DS4314 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
the data sheet states it.
The ECONO-PAC and OCTA-PAC families are the same construction in different core grades: a toroid with two identical windings brought out to four pads, so one part covers two inductance ranges.
Parallel gives 4.9 uH at 2.5 A; series gives 19.6 uH at 1.25 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.
Within the CTX5 family this is item 2 of 4 in the Eaton catalogue.
The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.
Can it be used as a transformer?
Yes, the two windings are on the same core, so it is a 1:1 transformer when used that way. The isolation between windings is not a safety barrier; check the construction note before using it across a mains barrier.
Why four times the inductance and not twice?
Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.
What is the volt-second rating?
The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd