Eaton CTX68-1P-R Toroid Power Inductor
Eaton CTX68-1P-R Toroid Power Inductor

Eaton CTX68-1P-R Toroid Power Inductor

Share
CTX68-1P-R: toroid power inductor, 68.4 uH.
    • Product Details
    • Download

    Eaton CTX68-1P-R Toroid Power Inductor

    CTX68-1P-R at a glance: toroid power inductor, 68.4 uH.

    Ratings at a Glance

    ParameterValue
    Orderable part numberCTX68-1P-R
    Inductance, parallel68.4 uH
    Inductance, series274 uH
    DC current, parallel0.66 A
    DC current, series0.33 A
    DCR, parallel maximum373 mOhm
    DCR, series maximum1.49 Ohm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    The Figures Explained

    A toroid has no air gap in the usual sense: the gap is distributed through the powder core, which is why the saturation curve is soft and why these parts hold inductance further into the current range than a gapped ferrite.

    Parallel gives 68.4 uH at 0.66 A; series gives 274 uH at 0.33 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX68 family this is item 1 of 4 in the Eaton catalogue.

    Series Positioning

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    Why four times the inductance and not twice?
    Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.

    Why four times the inductance and not twice?
    Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.