    CTX68-3P-R at a glance: toroid power inductor, 68.8 uH.

    Specification Table

    ParameterValue
    Orderable part numberCTX68-3P-R
    Inductance, parallel68.8 uH
    Inductance, series275 uH
    DC current, parallel0.84 A
    DC current, series0.42 A
    DCR, parallel maximum328 mOhm
    DCR, series maximum1.31 Ohm
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data DS4314

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data DS4314; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    The ECONO-PAC and OCTA-PAC families are the same construction in different core grades: a toroid with two identical windings brought out to four pads, so one part covers two inductance ranges.

    Parallel gives 68.8 uH at 0.84 A; series gives 275 uH at 0.42 A. The inductance ratio is about 4 to 1, which is the turns-squared rule at work.

    Within the CTX68 family this is item 3 of 4 in the Eaton catalogue.

    Series Positioning

    The ECONO-PAC and OCTA-PAC ranges run from under 1 uH in parallel to several millihenry in series, all two-winding toroids on powder cores.

    • The windings are not a safety isolation barrier. Do not use the part across a mains barrier without checking the construction.
    • Typical applications: computer and portable power devices; lcd panels, dvd players; inductor: dc-dc converters; buck, boost, forward, and resonant converters; noise filtering and filter chokes.
    • Design note: parallel and series are two different parts in one body. Fill in the connection on the drawing before release.

    Frequently Asked Questions

    What is the volt-second rating?
    The flux swing the core can take per switching cycle before saturation. At a given switching frequency it converts directly to the maximum applied voltage.

    Why four times the inductance and not twice?
    Inductance scales with the square of the turns. Two identical windings in series double the turns, so the inductance goes up by four while the current rating halves because the wire is now shared in one path.