Eaton DR1030-100-R 10 uH Shielded Power Inductor, 2.8 A
Eaton DR1030-100-R 10 uH Shielded Power Inductor, 2.8 A

Eaton DR1030-100-R 10 uH Shielded Power Inductor, 2.8 A

Share
Eaton DR1030-100-R: Shielded Drum Core Power Inductor, 10 uH, 2.8 A, DCR 40.2 mOhm.
    • Product Details
    • Download

    Eaton DR1030-100-R 10 uH Shielded Power Inductor, 2.8 A

    DR1030-100-R at a glance: shielded drum core inductor, 10 uH, 2.8 A Irms, 3.18 A Isat, DCR 40.2 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberDR1030-100-R
    Rated inductance10 uH ±20%
    Open circuit inductance (OCL)10.4 uH
    Irms (40 °C rise)2.8 A
    Isat3.18 A
    DCR typical @ 20 °C40.2 mOhm
    DCR maximum @ 20 °C48 mOhm
    K-factor (Bp-p = K x L x dI)7
    Package10.5 x 10.3 mm footprint, 3.0 mm height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    The Figures Explained

    Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.

    Copper loss grows with the square of the current, so 40.2 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.

    Isat is the peak current for approximately 35% rolloff at +25 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.

    Where This Series Fits

    The DR1030 is the low-profile member of the 10.5 x 10.3 mm DR family. Eaton builds the same 10.5 x 10.3 footprint in three heights - 3.0, 4.0 and 5.0 mm - and the height is what you trade for current. The 3.0 mm part fits under a shield can or into a slim chassis; for the same inductance the taller versions will carry more current.

    • Typical applications: LED/LCD backlighting, HDTV, server and desktop power supplies, notebook regulators, graphics cards, point-of-load modules.
    • At 3.0 mm this is the thermally tightest of the three heights - check the self-heating at the current you actually need before banking on the headline Irms figure.
    • Data sheet 4132.

    Putting It to Work

    10 uH sits in the middle of the range, and the trade at that point is explicit: 40.2 mOhm of DCR against 3.18 A of saturation headroom.

    Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.

    Frequently Asked Questions

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    How is it mounted?
    Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr1030-shielded-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.