| Parameter | Value |
|---|---|
| Orderable part number | DR1030-100-R |
| Rated inductance | 10 uH ±20% |
| Open circuit inductance (OCL) | 10.4 uH |
| Irms (40 °C rise) | 2.8 A |
| Isat | 3.18 A |
| DCR typical @ 20 °C | 40.2 mOhm |
| DCR maximum @ 20 °C | 48 mOhm |
| K-factor (Bp-p = K x L x dI) | 7 |
| Package | 10.5 x 10.3 mm footprint, 3.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
Copper loss grows with the square of the current, so 40.2 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Isat is the peak current for approximately 35% rolloff at +25 °C. In a buck converter the inductor current peaks at the top of the ripple, so the peak - not the average - is the number that has to stay below Isat with margin for the transient.
The DR1030 is the low-profile member of the 10.5 x 10.3 mm DR family. Eaton builds the same 10.5 x 10.3 footprint in three heights - 3.0, 4.0 and 5.0 mm - and the height is what you trade for current. The 3.0 mm part fits under a shield can or into a slim chassis; for the same inductance the taller versions will carry more current.
10 uH sits in the middle of the range, and the trade at that point is explicit: 40.2 mOhm of DCR against 3.18 A of saturation headroom.
Thermal design is not optional here. The rated current assumes a 40 °C rise with the part in free air on a stated pad; inside a closed box, on a thin board, next to a hot IC, that assumption is gone.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
How is it mounted?
Surface mount, reflow compatible and J-STD-020 compliant. The pad layout on the data sheet is the one the ratings were measured on.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd