Eaton DR1030-101-R 100 uH Shielded Drum Core Inductor
Eaton DR1030-101-R 100 uH Shielded Drum Core Inductor

Eaton DR1030-101-R 100 uH Shielded Drum Core Inductor

Share
Eaton DR1030-101-R: Shielded Drum Core Power Inductor, 100 uH, 0.86 A, DCR 375 mOhm.
    • Product Details
    • Download

    Eaton DR1030-101-R 100 uH Shielded Drum Core Inductor

    DR1030-101-R at a glance: shielded drum core inductor, 100 uH, 0.86 A Irms, 1.05 A Isat, DCR 375 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberDR1030-101-R
    Rated inductance100 uH ±20%
    Open circuit inductance (OCL)100 uH
    Irms (40 °C rise)0.86 A
    Isat1.05 A
    DCR typical @ 20 °C375 mOhm
    DCR maximum @ 20 °C450 mOhm
    K-factor (Bp-p = K x L x dI)2.4
    Package10.5 x 10.3 mm footprint, 3.0 mm height
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant (-R suffix)

    Reading the Data Sheet

    The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.

    DCR 375 mOhm is the conduction loss: at the rated current it dissipates about 0.28 W, and that heat has to leave through the terminals and the board.

    Saturation degrades with temperature on ferrite. Isat is the peak current for approximately 35% rolloff at +25 °C, and the hot value is the one that matters under a hood or inside a sealed enclosure.

    Where This Series Fits

    The DR1030 is the low-profile member of the 10.5 x 10.3 mm DR family. Eaton builds the same 10.5 x 10.3 footprint in three heights - 3.0, 4.0 and 5.0 mm - and the height is what you trade for current. The 3.0 mm part fits under a shield can or into a slim chassis; for the same inductance the taller versions will carry more current.

    • Typical applications: LED/LCD backlighting, HDTV, server and desktop power supplies, notebook regulators, graphics cards, point-of-load modules.
    • At 3.0 mm this is the thermally tightest of the three heights - check the self-heating at the current you actually need before banking on the headline Irms figure.
    • Data sheet 4132.

    Putting It to Work

    Choose 100 uH when the ripple target is at the high end of the design window: the DCR stays at 375 mOhm and the saturation limit at 1.05 A leaves the transient room it needs.

    Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.

    Frequently Asked Questions

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    What is the difference between OCL and rated inductance?
    OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.

    Is the "-R" suffix important?
    Yes - it denotes the RoHS-compliant build. The same inductance without it is a different ordering code.

    Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

    Mechanical Dimensions

    eaton-dr1030-shielded-power-inductors-data-sheet mechanical dimensions and recommended pad layout

    Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message