| Parameter | Value |
|---|---|
| Orderable part number | DR1030-1R1-R |
| Rated inductance | 1.1 uH ±20% |
| Open circuit inductance (OCL) | 1.1 uH |
| Irms (40 °C rise) | 7 A |
| Isat | 9.5 A |
| DCR typical @ 20 °C | 6.5 mOhm |
| DCR maximum @ 20 °C | 7.9 mOhm |
| K-factor (Bp-p = K x L x dI) | 22 |
| Package | 10.5 x 10.3 mm footprint, 3.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
Every part on this page is a shielded drum core: a winding on a ferrite bobbin, capped by a ferrite shield. The construction sets both the inductance and the saturation behaviour, and it is why the same footprint can cover two decades of inductance without changing the land pattern.
Copper loss grows with the square of the current, so 6.5 mOhm matters most at full load. At half the rated current the winding loss drops to a quarter - which is why the part looks oversized for a light-load profile.
Isat is a magnetic limit, not a thermal one. Isat is the peak current for approximately 35% rolloff at +25 °C. Past it the inductance falls and the ripple climbs, and the current keeps flowing - nothing protects the switch except your own design margin.
The DR1030 is the low-profile member of the 10.5 x 10.3 mm DR family. Eaton builds the same 10.5 x 10.3 footprint in three heights - 3.0, 4.0 and 5.0 mm - and the height is what you trade for current. The 3.0 mm part fits under a shield can or into a slim chassis; for the same inductance the taller versions will carry more current.
1.1 uH sits at the low end of the range, and the trade at that point is explicit: 6.5 mOhm of DCR against 9.5 A of saturation headroom.
The loss budget is the whole story with a power inductor: core loss grows with frequency and flux swing, copper loss grows with current, and the two meet at a different point for every inductance in the series.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
What is the K-factor for?
It converts the peak-to-peak ripple into a flux swing: Bp-p = K x L x dI, with Bp-p in mT and L in uH. That flux swing is what you enter on the core loss graph.
Is Isat a thermal limit?
No. Isat is where the core starts to saturate and the inductance falls by the stated percentage. Temperature is governed by Irms and the board, separately.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.