| Parameter | Value |
|---|---|
| Orderable part number | DR1030-220-R |
| Rated inductance | 22 uH ±20% |
| Open circuit inductance (OCL) | 22.8 uH |
| Irms (40 °C rise) | 1.8 A |
| Isat | 2.19 A |
| DCR typical @ 20 °C | 95.5 mOhm |
| DCR maximum @ 20 °C | 115 mOhm |
| K-factor (Bp-p = K x L x dI) | 5 |
| Package | 10.5 x 10.3 mm footprint, 3.0 mm height |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant (-R suffix) |
The drum core is the workhorse of DC-DC magnetics. It is cheap to build, it saturates in a predictable way, and with a ferrite shield over the winding it can be placed within a few millimetres of an IC without the field coupling into the die.
DCR 95.5 mOhm is the conduction loss: at the rated current it dissipates about 0.31 W, and that heat has to leave through the terminals and the board.
The saturation current is measured at a defined roll-off, and Eaton states the percentage on the data sheet: Isat is the peak current for approximately 35% rolloff at +25 °C. Read the number with the percentage in hand, because "saturation" means different things at 25% and at 40%.
The DR1030 is the low-profile member of the 10.5 x 10.3 mm DR family. Eaton builds the same 10.5 x 10.3 footprint in three heights - 3.0, 4.0 and 5.0 mm - and the height is what you trade for current. The 3.0 mm part fits under a shield can or into a slim chassis; for the same inductance the taller versions will carry more current.
Choose 22 uH when the ripple target is in the middle of the design window: the DCR stays at 95.5 mOhm and the saturation limit at 2.19 A leaves the transient room it needs.
Efficiency is set by where you sit on the loss curve, and the curve moves with switching frequency. A part that is excellent at 300 kHz can be mediocre at 1 MHz with the same current, because the core loss term takes over.
Why does the DCR have a typical and a maximum?
Winding resistance varies with wire tolerance and termination. The maximum is the guaranteed limit and the one to use for a loss budget that has to hold in production.
Can I run it above the rated current?
Briefly, if the peak stays below Isat and the average heating stays within the temperature rise the board can actually remove. There is no built-in protection.
What is the difference between OCL and rated inductance?
OCL is measured at zero DC bias. The rated inductance is the value the part still has at its rated current, and that is what the ripple calculation needs.
Design note: use the maximum DCR for the loss budget, keep the peak current below Isat with margin for the transient, and remember the 40 °C rise assumes free air on the recommended pad.

Dimensional drawing and recommended PCB pad layout from the Eaton data sheet. Tolerances and pad dimensions are as printed on the drawing; check the outline against your layout before release.